Service | Concept2

Model C Troubleshooting

Damper Falls to Lowest Position

Symptom

The damper doesn't stay in position and falls down.

Resolution

You will need a Damper Button, part number 1521, from Concept2. The plastic damper button will act as a wedge and put outward pressure on the damper, keeping it in place. Insert it into one of the perforated holes following the instructions here: Damper Button Installation.